Shanghai, China
Business Type:
Manufacturer/Factory, Trading Company
Registered Capital:
10000000 RMB
Plant Area:
501~1000 square meters
Management System Certification:
ISO 9001, ISO 14000
Average Lead Time:
Peak season lead time: one month
Off season lead time: one month
OEM/ODM Service
Sample Available

UPS, Battery, Power Supply manufacturer / supplier in China, offering Valve Regulated and Maintenance Free 2V 2000AMP Solar Battery for 5k Home Solar System, High Frequency Online UPS (1-20kv), UPS, Uninterruptible Power Supply, Online UPS, 1/1, 3/1 1kVA/0.8kw and so on.

Gold Member Since 2017
Audited Supplier
Supplier Homepage Products Solar Battery Valve Regulated and Maintenance Free 2V 2000AMP Solar Battery for 5k Home Solar System

Valve Regulated and Maintenance Free 2V 2000AMP Solar Battery for 5k Home Solar System

Get Latest Price
Min. Order / Reference FOB Price
100 Pieces US $360-375/ Piece
Port: Shenzhen, China
Production Capacity: 50000 Piece/Pieces Per Week
Payment Terms: L/C, T/T, D/P, Western Union, Paypal
Type: Lead-Acid Batteries
Usage: UPS, Electric Power, Lighting, Electric Bicycle, Boat, Solar Power
Nominal Voltage: 2V
Discharge Rate: Medium Discharge Rate
Shape: Square Battery
Electrolyte: Acid

You Might Also Like

Loading...

Basic Info

Installation: Fixed
Rechargeable: Chargeable
Eom/ODM: Yes
Sealed Type: Sealed
Maintenance Type: Free
Weight: 130kg
Nominal Capacity: 2000ah
Color: Black
Warranty: 1 Year: 1 Year
Container Material: ABS
Terminal: Copper
Plates: Lead Calcium Alloy
Trademark: SUPSTECH
Transport Package: Paper Carton and Fuming Wood Pallet
Specification: 490*350*344mm
Origin: Shenzhen
HS Code: 8507200000

Product Description

  Valve Regulated and Maintenance Free 2V 2000AMP Solar Battery for 5k Home Solar System
Home Solar System Battery from SUPSTECH
This range is the most common standard and the first generation delicate product which is designed with AGM (Absorbent Glass Mat) technology, high performance plates and electrolyte. The definition of NP is coming from general purpose. Therefore, this range product has possessed various applications for common power backup system.
Nominal Voltage: 2V
Capacity: from100AH to 3000AH
Design Life: 8- 10 years
Applications: Emergency lighting system, electric tool, geodesic apparatus, fire alarm, safety alarm, UPS system, control system, medical treatment equipment, backup power system, portable power, power system, railway system, ship equipment, military equipment, telephone switching system, etc.
Characteristic: special lead- calcium alloy plate and high purity additive ensure long life of battery, high purity electrolyte and additive make battery low self-discharge , valve-regulated and sealed configuration, no dissociative acid, maintenance-free operation, good consistency and no need uniform charge. 
 
Characteristics of Valve Regulated Lead Acid Battery SUN2V- 2000

Valve Regulated and Maintenance Free 2V 2000AMP Solar Battery for 5k Home Solar System
Specifications of Big-sized SUN2V
Valve Regulated and Maintenance Free 2V 2000AMP Solar Battery for 5k Home Solar System

Stucture of SUN2V-2000
Valve Regulated and Maintenance Free 2V 2000AMP Solar Battery for 5k Home Solar System
Compatible applications
Valve Regulated and Maintenance Free 2V 2000AMP Solar Battery for 5k Home Solar System

Factory Pictures 

Valve Regulated and Maintenance Free 2V 2000AMP Solar Battery for 5k Home Solar System

SAFTY PRECAUTIONS
 
FORBIDDANCE
1 Medical equipment
2 Any application possible to cause fatal injury.
3 Any application or battery inversion (safety valve at the bottom)
 
RISKS
1. Do not cause short circuit in the positive and negative terminals of batteries lf so, there will be risks of leakage, fire and explosion.
2. Do not use batteries in sealed rooms and boxes.
3. Batteries would produce hydrogen If naked flame or short circuit occurs, there Will be a risk or explosion and tire accident while installing batteries simultaneously, please stay away from the heat source.
4. When the acid leaked from batteries and touches the skin and clothes, please rinse with plenty of water. If it goes into eyes, it will cause blindness.
 
 WARNINGS
1. Please implement regular inspections in compliance with the national standards and industry standards related to batteries. Please change batteries if the life span is exceeded.
2. Please do not use insulated Wires and soft vinyl chloride films containing plasticizers. In addition, please do not use organic solvents and detergents, such as banana oil, gasoline, essential oil, rat oil and others. If these materials come into contact with the battery shell, it will split or crack causing battery leakage, fire, etc.
3.Waste lead acid batteries are toxic and hazardous. Please comply with the environmental regulations, and do not arbitrarily throw away used lead acid batteries, which are hazardous waste. You can contact recycling organizations with environmental qualifications to recycle them, or refer to the local environmental protection departments.
 
ATTENTIONS
1. For safety precautions, the surfaces of battery cabinets and holders should be well insulated and acid resistant coated. Cabinets and holders of metal materials are strictly prohibited to directly load batteries without any insulation protection treatment
2. For safety precautions, the insulation layer can be placed at the bottom or the battery cabinets 3nd holders before the installation, so as to isolate the electrical connections between the battery body and the cabinets and holders The insulation layer can also prevent the following risks: sulfuric acid leakage
arisen from rupture of battery container, fire accidents resulted from the electric leakage circuit among the metal cabinets, holders and batteries due to acid liquid corrosion in cabinets and holders. The insulating layer materials selected should not cause corrosion to the battery container. Meanwhile, they
should have heat resistance, acid resistance, certain mechanical strength (not getting damaged owning to long-term battery pressure), and would take the forms of insulating strips or trays.
3. Make sure to tighten the battery connection according to the size of torques, and check frequently. Loose connection may cause fire accidents.

ALL SPECIFICATION AND APPEARANCE ARE JUST FOR YOUR REFERENCE, WE HAVE RIGHT TO CHANGE ANY SETAILS WITH ANY NOTICE.

Send your message to this supplier

*From:
*To:
avatar Mr. Frank Zeng
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now